6
SINGLE STAGE UNITS ONLY
The gas valve regulator spring must be replaced on all single stage gas furnaces and packaged gas/electric units.
Replace the gas valve regulator spring with the propane gas regulator spring from the proper spring kit. Follow the
manufacturer’s instructions provided in the spring kit. Discard all unused spring kits. Two-stage units do not
require a spring change.
Gas Valve Regulator Spring Replacement
Honeywell
OFF
ON
OUTLET
INLET
Outlet (Manifold)
Pressure Tap
Pressure Regulator
Adjustment
(Under Cap Screw)
Inlet Pressure Tap
Gas Valve
On/Off
Control Knob
PSI IN
O
F
F
O
N
2
Outlet Pressure Tap
1/8 N.P.T., Plugged
Steel
Pressure Regulator
Adjustment (Under
Cap Screw)
Mates With
HONEYWELL
Q3450* Pilot
Harness
Mates With
Socket Housing
Control Module
IGNITOR
CONTROL
OUTLET
INLET
Pilot Tube
Connection
Outlet (Manifold)
Pressure Tap
(Side of Valve)
Pressure Regulator
Adjustment
(Under Cap Screw)
Gas Valve
On/Off
Control Lever
In ON Position
Inlet Pressure Tap
(Side of Valve)
INLET
OUTLET
Figure 8
Robertshaw
Model 7222
Pressure Regulator
Adjustment
(Under Cap Screw)
OUTLET
INLET
Gas Valve
On/Off
Control Knob
Inlet Pressure Tap
(Side of Valve)
Outlet (Manifold)
Pressure Tap
High Manifold
Regulator Adjustment
Screw (Under Cap)
Inlet Pressure Tap
(Side of Valve)
OFF
ON
PM
C
HI
Low Manifold
Regulator Adjustment
Screw (Under Cap)
Outlet (Manifold)
Pressure Tap
(Side of Valve)
Outlet
Inlet
Gas Valve
Control Knob
Figure 6
White-Rodgers
Model 36E96 or 36E54
Figure 4
Honeywell
Model SV9501
O
F
F
ON
M
P
C
1
3
2
INLET
Pressure Regulator
Adjustment
(Under Cap Screw)
Inlet Pressure Tap
(Side of Valve)
Outlet (Manifold)
Pressure Tap
(Side of Valve)
Gas Valve
On/Off
Selector
Switch
OUTLET
Figure 5
White-Rodgers
Model 36E36 or 36E37
Figure 7
White-Rodgers
Model 36E22 or 36E23
O
F
F
O
N
IN
1/2PSI
Pressure Regulator
djustment (Under
Cap Screws)
Mates With
Honeywell
Q3450* Pilot
Harness
Outlet Pressure Tap
Gas Control/Valve
Knob
Inlet Pressure
Tap
OUTLET
INLET
Pilot Tube
Connection
Figure 3
Honeywell
Model SV9500
Figure 2
Honeywell
Model VR-8205
CAUTION
Spring kits are not interchangeable. A White-Rodgers gas valve requires a White-Rodgers
spring kit; a Honeywell gas valve requires a Honeywell spring kit, etc. Refer to Figures 2
through 8 for gas valve identification.
OUTLET
INLET
Pressure Regulator
Adjustment
(Under Cap Screw)
Gas Valve
On/Off
Selector
Switch
Inlet Pressure Tap
(Side of Valve)
Outlet (Manifold)
Pressure Tap
Figure 9
White-Rodgers
Model 36F22